Part Number Hot Search : 
SD335 1N128 UPD4722 DTA143T R1602 ZR78L033 R3K4X LAG640D
Product Description
Full Text Search
 

To Download IFC125-14 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 AC-DC
125 Watts IFC125 Series
* * * * * * * Small Size - 3.0" x 5.0" x 1.25"
xppower.com
Single, Triple and Quad Outputs Active PFC - Meets EN61000-3-2, -3 Current Share up to 4 Units Overvoltage & Overcurrent Protection Power Good Signal -25 C to +50 C Full Power
Specification
Input
Input Voltage Input Frequency Input Current * 90-264 VAC * 47-63 Hz * 0.8 A max at 240 VAC 1.8 A max at 100 VAC Inrush Current * 33 A max at 115 VAC 66 A max at 230 VAC Power Factor * 0.98 typical Earth Leakage Current * 0.5 mA max at 132 VAC/60Hz 0.825 mA max at 264 VAC/50Hz Input Protection * Internal 2.6 A fuse
General
Efficiency Isolation * 83% typical * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 6.66 W/In3 * Power Good - On = Logic High * >220 kHrs per Bellcore
Power Density Signals MTBF
Environmental
Operating Temperature * -25 C to +70 C, derate linearly from 100% at +50 C to 50% at +70 C Cooling * 5 CFM airflow required for 125 W Operating Humidity * 5-95% RH, non-condensing Storage Temperature * -40 C to +85 C Operating Altitude * 3000 m Shock * 15 G pk operating Vibration * 2.4 G, 5 Hz to 500 Hz, 3 axis
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Over/Undershoot Transient Response Ripple & Noise Overvoltage Protection Overtemperature Protection Overload Protection Short Circuit Protection Temperature Coefficient Remote Sense Current Share * * * * * * * * * * * * * * See table Not user-adjustable 5% maximum 5 W minimum load on V1 or V2 required to maintain regulation 1.5 s at 90 VAC 0.2-20 ms >28 ms min at full load See table See table 10% maximum 5% max. deviation, recovery to within 1% in 500 s for a 25% load change 1% pk-pk maximum or 5 Vout 50 mV maximum V1 & V2: 113-148%, auto recovery Unit shuts down, recycle input to reset
EMC & Safety
Emissions Harmonic Currents Voltage Flicker Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals * EN55022/CISPR22 and FCC, Class B conducted * EN61000-3-2 * EN61000-3-3 * EN61000-4-3, level 3 Perf Criteria B * EN61000-4-4, level 3 Perf Criteria B * EN61000-4-5, level 3 Perf Criteria B * EN61000-4-6 * EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Criteria A, B, B * EN60950, UL 60950, CSA950 per cUL, CE Mark LVD
* All outputs: 115-135%, auto recovery * Trip and restart (Hiccup mode) * 0.04% / C maximum * V1 only compensates for 0.5 V drop (not available on IFC125-31) * Up to 4 supplies to share within 10%
1
AC-DC
Models and Ratings
Vnom 24.0 V 5.0 V 2.5 V 3.3 V Notes
1. 2. 3. 4.
IFC125
Output 2 Imax 0.5 A 5.0 A 15.0 A 15.0 A Reg(1) 5% 5% 4% 4% Vnom -12.0 V 12.0 V 12.0 V Output 3 Imax 0.5 A 5.0 A 5.0 A Reg(1) 5% 5% 5% Vnom Output 4 Imax Reg(1) Model Number IFC125-14 IFC125-31 IFC125-40-1 IFC125-42-3
Output 1 Imax 5.2 A 16.5 A 12.5 A 10.0 A
Reg(1) 3% 4% 2% 2%
Vnom 12.0 V 12.0 V 5.0 V 5.0 V
-12.0 V -12.0 V
0.5 A 0.5 A
5% 5%
Total regulation includes tolerance, line regulation and load regulation. Maximum output power not to exceed 125W with 5 CFM forced air or 70W with convection cooling. For IFC125-40-1 and -42-3, a maximum of 80W combined +2.5V or +3.3V and +5V outputs with 5CFM of forced air cooling or 40W with convection cooling. 5W minimum load required to maintain regulation.
Mechanical Details
Connector Pin-outs Conn Pin IFC125-31 IFC125-40-1 IFC125-42-3 1 Neutral Neutral Neutral J1 2 3 Line Line Line 1 -12 VDC -12 VDC -12 VDC 2 +12 VDC +12 VDC +12 VDC 3 Not Used +2.5 VDC +3.3 VDC 4 Not Used +2.5 VDC +3.3 VDC 5 Not Used +2.5 VDC +3.3 VDC 6 DC GND DC GND DC GND 7 DC GND DC GND DC GND J2 8 DC GND DC GND DC GND 9 DC GND DC GND DC GND 10 DC GND DC GND DC GND 11 +5 VDC +5 VDC +5 VDC 12 +5 VDC +5 VDC +5 VDC 13 +5 VDC +5 VDC +5 VDC 14 +5 VDC +5 VDC +5 VDC 1 0 V Sense 0 V Sense 0 V Sense J3 2 Not Used +2.5 V Sense +3.3 V Sense 3 Power Good Power Good Power Good
5.00 (127.0) 0.23 (5.7) 4.55 (115.6)
O 0.16 (4.1) (4 places)
3.00 (76.2) 2.55 (64.8)
Pin #1
J1 - Input connector
Safety ground connection point Pin #1
J2 - DC output connector for IFC125-31, -40-1, 42-3. (see pin-out table)
Pin #1
J3 - Remote Sense/ PG connector
Fastener clearance area (4 places)
Lock washer
Screws shown for reference only
1.00 1.25 (25.4) (31.8)
0.06 (1.5)
0.19 (4.8)
PCB
Molex Mating Connectors IFC125-31 & -40-1
J1 Housing Pins Housing Pins Housing Pins 09-50-8031 08-52-0113 09-50-8141 08-52-0113 22-01-3037 08-50-0114
IFC125-42-3
90-50-8033 08-52-0113 09-50-8143 08-52-0113 22-01-3037 08-50-0114
Notes
1. All dimensions in inches (mm). 2. Weight 0.68 lb (310 g) approx (-14 models 0.6 lb, 270g). J2 J3
16-Aug-05


▲Up To Search▲   

 
Price & Availability of IFC125-14

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X